Escalator Requirements
CZPT configuration | |
Inclination (°) | thirty(35) |
Action width (mm) | 600/800/1000 |
Horizontal actions | 2/2 three/3(for 30°), two/two for 35° |
Pace(m/s) | .5 |
Motor power | 8/11/15KW |
Handrail bracket | Stainless steel |
Increase height for 600 | 3000≤H≤6000/ 6000≤H≤7200 |
Rise height for 800 | 3000≤H≤4800/4800≤H≤6000/6000≤H≤6400/6400≤H≤7200 |
Rise height for a thousand | 3000≤H≤4800/4800≤H≤6000/6000≤H≤6400/6400≤H≤7200 |
Technological innovation Benefits
one.VVVF push
two.Secure basic safety program
three.Best managing overall performance
four.Innovative manage system(German technological innovation)
5.Comfortable and productive
6.Reduced sounds and power-saving
Security Features
1.Deficiency of phase, mistake phase protection:
If absence of section (relocating-wander) will or eror section has been checked out, the escalator automatically end the procedure.
two.Motor over-Ioad defense:
When the current exceeds fifteen% of the recent rating, the escalator will automatically slop the operation.
three.CZPTal equipment loop security:
It provides the computerized circuit disconnecting gadget to protect the circuit and mains components of the escalator (moving-stroll).
4.Handrail inlet security:
When some overseas substance has been clipped in the handrail inlet. the escalator (relocating-wander) will routinely slop the operation.
5.Comb plate safety system:
When some international compound has been clipped in or amongst the combs.the escalator (shifting-walk) will automatically cease the operation.
6.Step sagging defense unit:
When there is abnormal step bending, the escalator (shifting-walk) will end the operation before the stage coming into into the comb plate
seven.Broken drive-chain protection unit:
When the travel-chain has been above-stretched or it is damaged, the escalator (transferring-walk) will instantly quit the procedure
8.Damaged step chain protection:
When the step (plate) chain has been above-stretched or it is broken, the escalator (moving walk) will routinely slop the operation.
9.In excess of-pace protection:
When there is above-speed to the escalator (transferring walk),it will automatically end the operation.
ten.Direction reversal safety:
When it will come the unintentional reve rsal of the route of vacation, the escalator (moving stroll) will automatically stop the procedure.
11.Security line:
The yellow artificial resin stability line is found in the front situation and two sides of the escalator tread so that the passengers will not tread in-between the edge of the adjacent step and the group lengthened skirt panel. The security line on the two sides of the action is increased than the tread area. (The moving-stroll offers the selective yellow spray-palmed security line.)